Thermogravimetric Analyser et250

Thermo Gravimetric Analyser - TGA et250

Overview

Thermogravimetric Analysis (TGA) is a widely utilized method for evaluating key properties of materials that experience either weight loss (or) weight gain as a result of thermal decomposition, oxidation (or) release of volatile substances (or) release of moisture/water vapors.

Thermogravimetric Analysis continuously measures the mass loss of the sample while temperature of a sample is changed over time under a controlled atmosphere.

The elite TGA et250 is Macro Thermogravimetric Analysers designed to measure Moisture, Ash, Volatile Matter, Fixed Carbon and Loss-on-Ignition content of various materials using loss on drying technique. Mass loss of the sample is measured as a function of the temperature by controlling the atmosphere and ventilation rate. The TGA et250 allows up to 19 samples to be analyzed simultaneously.

Thermogravimetric Analyser et250
  • 20 Position carousel to accommodate 19 samples and one reference
  • Programmable lifting of the upper furnace for enhanced stability & durability
  • Possible to utilize various atmospheres
  • User friendly operation
  • Precise Weighing
  • The TGA et250 Thermogravimetric Analyser furnace temperature is monitored by two thermocouples. One thermocouple to monitor the furnace temperature and the other thermocouple to monitor the Sample temperature.
Specifications TGA et250
Temperature Range Programmable from ambient to 1100°C
Temperature Control Precision ±2 deg C (or) ±2% of set point temperature
Temperature Stability ±2 deg C (or) ±2% of set point temperature
Ramp Rate Programmable from 10°C /minute to 50°C / minute
Balance Integrated Balance
Balance Resolution 0.0001g (0.1mg)
Balance Readability 0.0001g (0.1mg)
Weight Loss 0-100%
Sample Size Upto 10 grams based onthe sample type and its characteristics
Number of Samples 19 Samples +1 Reference
Number of Carousels One for crucibles & crucibles lids
Carousel Material Metal or Ceramics
Weighing Precision 0.02% RSD (on inert Samples)
Electrical Power Requirements 230V (± 10%) / single phase / 50/60Hz / 15A
Computer 230V (± 10%) / single phase / 50/60Hz / 2A
Item Name Part Number
Single Furnace Thermogravimetric Analyser with single carousel TGA et250
Double Furnace Thermogravimetric Analyser with two carousels TGA et250D
Ceramic crucibles et100-1460
Ceramic crucible covers et100-0460
Ceramic carousel for Crucible covers, 20 Positions et107-3210
Ceramic carousel for Crucibles, 20 positions et107-3730
Metal Carousel for Crucible covers, 20 positions et112-2540
Metal Carousel for Crucibles, 20 positions et112-2550