Vacuum (Cold / Wall) Chamber Furnace

Vacuum (Cold / Wall) Chamber Furnaces

1800°C to 2000°C Maximum

Overview

The BVT is a cold wall vacuum furnace designed to operate at 1800°C in vacuum and 2000°C in neutral or reducing atmosphere.

Vacuum (Cold / Wall) Loading Chamber Furnaces
  • Choice of high or low vacuum.
  • Heating by high grade graphite elements.
  • Fully automatic "fail safe" system is fitted as standard.
  • The top loading swing door is fully interlocked for safety.
  • Temperature control is by thermocouple up to 1800°C and by optical pyrometer above 1800°C.
  • The furnace is equipped for use with inert/reducing gases with automatic purging for maximum purity of atmosphere. A simple flowmeter calibrated for argon is fitted.
  • Chamber access is via a pneumatically operated lid lift system with manual swing aside to clear the furnace top.
Model Max Temp (°C) Max Cont (°C) Max Chamber
Dims (mm)
HxWxD
External Case
Dims (mm)
HxWxD
Chamber Capacity (Litres) Max Power (Kw) Volts Phase
BVT20/3 2000 2000 100dia x 150 1400x1150x650 2.4 16.0 400 2
BVT20/5 2000 2000 150dia x 200 1400x1150x650 4.7 24.0 400 2